Standard Wound series Filter Cartridge
Home> Product
SFW standard string wound filters - PP
Length: 254mm/250mm, 508mm/500mm, 762mm/750mm, 1016mm/1000mm
Filtering precision range: 1μ - 100μ
Outer diameter: 60/63±1mm
Inside diameter: 28/30mm
Material: common pp yarn
Packing: Carton & Poly bag
Specification


STRUCTURE
 

String wound filter cartridge consists of multi-hole frames wound closely with textile fibers. Diverse kinds of filtering precision can be realized by controlling the winding density. As the outer bore diameter is larger than the inner one, the filter cartridges have a good deep-level filtering capability.  SFW standard series has competitive price and acceptable quality and stable performance.

FEATURES 
 
•  Resonable price
•  Stable performance
 
MAIN TECHICAL SPECIFICATION 

•  Dimension: Outer diameter Ø63±1mm Inner diameter Ø 28mm or Ø 30mm 
•  Maximum operating Pressure: 0.5MPa (72.5psi)
•  Temperature:  60℃(140℉)

TYPICAL APPLICATIONS

•  PCB & metal finishing
•  Industrial liquid treatment
•  Waste water treatment
•  Other applications

TABLE 1

FLOW OF FILTER CARTRIDGE 
 
The recommended flow for the filter cartridges in service is shown in the table (L/h for a 250㎜filter cartridge)
Micron Rate(μm) Viscosity
1cs(water) 30cs 60cs 120cs 250cs
0.5 70 60 40 25 -
1 150 90 60 40 -
3 300 120 80 50 -
5 500 170 120 60 45
10 800 300 140 70 60
25 1200 670 300 150 130
50 1200 880 440 180 160
75 1200 1200 690 230 200
100 1200 1200 750 270 220
Note:
1. The flow of each 250mm
10inchfilter cartridge should not exceed 1200 L/H (317G/H), otherwise its precision may be affected.
2. The flows shown in the above table are only the recommended values. The actual flow of the filter cartridge in service may change due to the liquid nature, temperature, the nature of the eliminated particles, the contents of the particles, etc.
3. It is recommended that a new filter cartridge used in the first time should work under a pressure drop of 0.1 - 0.3 bar (1.45 – 4.35psi ), while the final pressure drop for the filter cartridge exchange is set at 2.5 bar. For the filter cartridge whose precision is lower than 10μm, the pressure drop for the filter cartridge exchange had better be set at 1.0 -1.5 bar (14.5 – 21.8psi).

  
 
TABLE 2

DIRT HOLDING CAPACITIES



TABLE 3

ORDERING INFORMATION


SF W 205 P 63 P 28
           A     B     C      D

SF Brand name
W Filter type- W= string wound, PP= melt blown, PPL= PP pleated, CTO= carbon block
A Length- 10/20/30/40, inches. 250/500/750/1000, mm.
B Rating- 0.5/1/3/5/10/25/50/75/100/150/200/250/300 microns
P Yarn material- P= polypropylene, C= cotton, PE= polyester, GF= glass fiber
C Outer diameter: 60/63/110/152 mm
P Inner core material- P= polypropylene, S= stainless steel
D Inner diameter- 28/30/70/100mm